MSD Software Manual PRELIMINARY Release Chapter 8 The Signal Generator.
8 The Signal Generator.
The Tone Generator menu controls all signal generator functions. To access
this menu press [SIG GEN] in ‘Full Feature Mode’.
Please note that the level and frequency for Pulse, EBU, Pink and White Noise
Test signals are set in the [SINE] menu.
The Test Signal Generator enables a low distortion signal to be fed into the
Audio Matrix just like any other external audio signal. This means that the
Signal Generator via the Audio Matrix can be set to output a test signal on any
physical output available on a MSD model.
The Signal Generator shows up in the Input Matrix line number #53,54 (Tone)
and can be treated just like any other source. In this way it is also possible to
feed the output from the Signal Generator directly to the PPM Meter or to any
of the other functions found in the MSD. For the MSD Models with no physical
outputs it is still possible to use the Signal Generator as an internal test
generator.
The active Test Signal is indicated by the highlighted green square.
To disable the signal generator on a destination, just select another source for
that destination.
8.1 Sine Wave Test Tone Generator.
Enter the [SINE] menu to adjust the frequency and the amplitude for any of
the available test tones. Setting the frequency and amplitude is done by the
arrow [] / [] keys. The frequency can be set in the range of 31Hz to
19952Hz in predefined steps. The amplitude adjustments (measured in dBu)
are made in steps of +/-0.1dB, but adjustment speed can be increased by a
factor ten (+/-1.0dB) by pressing the [x10] key. If active, the [x10] highlighted
with a green square.
Note for PT0660M users: It is possible to adjust the frequency and output
level using the wheeler. Pressing the wheeler determines which value to be
adjusted. The [#2] key above the wheeler will toggle the [x10] option. The
[#1] key above the wheeler will exit the sine wave setup menu.
8.2 Pulse Modulation Tone Generator.
The PULSE function changes the sine wave signal from the first channel (#53)
from the Sine Wave Generator into a ‘pulse’ (chopped sine wave). The second
channel (#54) from the Sine Wave Generator is not affected. The ‘Pulse’ and
‘Pause’ duration times is set in milliseconds using the arrow [] / [] keys.
Single millisecond increment adjustments are made by ‘clicking’ these keys.
For greater increments, keep the key pressed down.
The amplitude of the pulse signal is adjusted in the [SINE] menu. Please refer
to section 8.1 for information on how to do this.
Note for PT0660M users: It is possible to adjust the pulse and pause timing
using the wheeler. Pressing the wheeler determines which value to be
adjusted. The [#1] key above the wheeler will exit the pulse setup menu.