Page 15 of 108
Cable Wash
Before the washing procedure starts!
In order to maintain the flexibility of the cables, it is important that the cable is placed in such a way that the cable’s own weight does not strain the
coil during the washing process.
This can be done by placing the cable ON the bed or another form of support for the cable.
Please see the examples in the below pictures
Maintenance
Valid for all LINAK products
The LINAK products must be cleaned at regular intervals to remove dust and dirt and inspected for mechanical damage, wear and breaks,
- worn out parts must be replaced.
The LINAK products are closed units and require no internal maintenance.
Only type IPX6 is waterproof and type IPX6 Washable tolerates being washed in tunnels.
The LINAK products must be IPX6 Washable when cleaning in wash tunnels. Make sure that the plugs are correctly fitted with O-rings before washing.
O-rings: When individual parts are replaced in a LINAK IPX6 or IPX6 Washable system, the O-rings on all parts, must be replaced at the same time.
On control boxes with a replaceable mains fuse, the O-ring in the fuse cover must be replaced every time the cover has been removed.
The O-rings must be greased in water free vaseline when replacing them. Make sure that the counterpart - the socket - is clean and undamaged.
Valid for all LINAK actuators and lifting columns
Actuators/lifting columns must be inspected at attachment points, wires, piston rod, cabinet, and plugs, as well as checking that the actuator/
lifting columns function correctly.
To ensure that the pregreased inner tube remain lubricated the actuator must only be washed down when the piston rod is fully retracted.
Valid for all LINAK control boxes and handsets
Electronics must be inspected at attachment points, wires, cabinet, and plugs.
Inspect the connections, cables, cabinet, and plugs, and check for correct functioning (does not apply to battery versions).
With the exception of the CS16 the control box is sealed and maintenance free.
Inspect at regular intervals that the ventilation aperture on the external battery is positioned correctly and is intact throughout its length,
approx. 20 mm., see figure 1.
Environmental conditions
Storage and transport
Operating
Temperature
Relative humidity
Atmospheric pressure
5°C to 40°C
20% to 90% @ 30°C – not condensing
800 to 1060 hPa (Rated to operate at an altitude ≤ 2000 m)
Storage
Temperature
Relative humidity
Atmospheric pressure
-10°C to +50°C
20% to 90% @ 30°C – not condensing
800 to 1060 hPa (Rated to operate at an altitude ≤ 2000 m)
Transport
Temperature
Relative humidity
Atmospheric pressure
-10°C to +50°C
20% to 90% @ 30°C – not condensing
800 to 1060 hPa (Rated to operate at an altitude ≤ 2000 m)
If the actuator is assembled in the application and is exposed to push or pull during
transportation, the actuator can be damaged.
Do not drop an actuator or otherwise damage the housing during disassembly or
transportation.
We do not recommend using an actuator which has been damaged.
Valid where nothing otherwise is stated under the specific products in a later section.
Przeglądanie stron 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 107 108

Komentarze do niniejszej Instrukcji

Brak uwag