Compliance to all relevant EC
directives
China
Pollution control mark (also
indicates recyclability)
ZERO standby power
Regulatory Compliance Mark:
The Australian Safety/EMC
Regulations
Protection against contact/
foreign matter (first character)
and water (second character)
as per EN60529
Alternating Current
Direct current
Lock function
Release function
Charge indicator
Safety switch/enable button
C/N XXXXXXX
ETL Recognized Component
mark for Canada and United
States
For complete description, see
ETL-marking on next page.
Insulation class
LINAK control boxes are available in insulation class 1 and insulation class 2.
Class 1 means with earth connection
Class 2 means without earth connection
When measuring the resistance in the earth connection in LINAK Control Boxes (class 1), it is recommended to use equipment, delivering a test
current of no less than 5A. The resulting voltage will correspond to the resistance in the earth connection. Test currents below 5A, would yield no
exact measurements.
Key to symbols
The following symbols are used on the label on the LINAK products.
If the application is insulation dielectric strength tested by applying a test voltage from the terminals of the mains connection to any
accessible metal parts (e.g. 4 kV for 240 V rated medical equipment), corona discharge or a momentary flashover might occur within
the actuator. This is not considered as an insulation breakdown.
However to avoid to overstress different types and levels of insulation, the control box and the actuator must be tested individually
(disconnected) with the respective dielectric strength test voltages (e.g. 4 kV for a 240 V rated control box and 500 V for the actuator).
This principle is in accordance with IEC 60601-1:2005, cl. 8.8.3.
UL Listing Mark
UL Listing Mark for Canada
UL Listing Mark for Canada
and the United States
UL Listing Mark
UL962
UL60601-1
UL1310
AS 3108
Australian approval mark
Various
TÜV Rheinland - LGA tested
Recognised
Component Mark
Canadian
Recognised - Component
Mark
Recognised
Component Mark for Canada
and the United States
PSE-Mark
IEC 60417-5172:
Class II equipment
Product with a thermofuse
IEC 60417-5957:
For indoor use only
IEC 60417-5222:
Safety isolating transformer,
general
IEC 60417-5840:
Patient part of type B
Patient part of type BF
Earth
IEC 60417-5019:
Protective earth; protective
ground
IEC 60417-5002:
Positioning of cell
ISO 7000-0434A:
Caution, consult
accompanying document
ISO 7000-1641
Operating instructions
Electronics scrap
Recycle
IPXX